Saline Chase Capability AND Patented Extravasation Detection
For almost 10 years, E-Z-EM has been offering EDA technology on our Empower injectors. Our EDA patch is the only clinically proven device that helps detect extravasations of contrast media. At 10 mL/sec it takes just 2 seconds for an extravasation to become clinically significant. And when ionic compounds are injected, the outcome can be even worse. Why accept the risk? E-Z-EM offers the proven solution featuring both high sensitivity and high specificity.
EmpowerCTA is a double-barrel CT injector designed for today's advanced CT procedures that
require a saline chase. Based on the EmpowerCT design and technology,
EmpowerCTA offers all the same features and benefits, including: patented
extravasation detection, tilt sensor/lockout, arming at the injector,
ease of use, flexibility and expandability.
Click here to learn more about all the Features and Benefits that come with every EmpowerCT and EmpowerCTA Injector System
PLUS...EmpowerCTA features
EXCLUSIVE Color-coded Syringe System.
Only the EmpowerCTA has clearly labeled control panel buttons to distinguish saline from contrast. Color-coded indicator lights alert the operator as to which syringe is in use to minimize syringe content confusion.
Intelligent System Interface.
Easy-to-use, Windows-based system interface automatically recognizes single or double-barrel modes for quick and easy injection setup.
Modular System. EmpowerCTA is based on EmpowerCT technology and offers all the same design concepts and safety features to maintain consumable standardization and help ensure a simple upgrade from the single barrel EmpowerCT Injector.
Now with option CAN-CiA DSP 425 protocol.
EmpowerSync allows for synchronization between the EmpowerCTA Injector System and the CT scanner, permitting automated and coordinated operation of both the scanner and the injector from the scanner’s control system. The following controls are available on the scanner: arm, run, pause and stop. EmpowerSync provides feedback to the scanner as to the injector’s operational status. This feature helps ensure consistent outcomes as scanning automatically begins based on contrast/injection parameters.
Click here to view/download "EmpowerCTA in Cardiac CT"
featuring Dr. Dennis Foley, Medical College of Wisconsin
Cardiac CT examines the
coronary arteries as well as the cardiac chambers and valves,
and the mediastinum of the lung.
Cardiac CT requires a
dense left heart (~300-350 HU), a partly dense right heart
(~100-150 HU), and a clear SVC.
Images Acquired
Using EmpowerCTA with Triphasic Injection Protocol
Phasing Protocol with EmpowerCTA Double-barrel Injector
Dr. Dennis Foley and colleagues have been using the EmpowerCTA
since purchasing their 64-channel scanner in mid-June 2004. Dr. Foley
developed a "triphasic injection protocol" for the EmpowerCTA
that addresses the unique opacification requirements of cardiac
CT. In the first phase, contrast is injected rapidly to produce a dense left heart. In the second phase, contrast is injected less rapidly to achieve a partly dense right heart. Finally, in the third phase, saline is injected to clear the superior vena cava.
Triphasic Injection Protocol
64-channel scanner
EmpowerCTA injector
Iso-osmolar contrast agent
320 mg iodine/mL
Acquisition
Heart rate 65
or 60 beats/min or less
Beta blockers
Rapid acquisition
Reproducible contrast injection
Two Ways
to Determine Patient's Circulation Time
Preliminary mini-bolus
Bolus tracking software
Coronary Arteriography:
64-channel Scanner
6 ccs/sec 10
secs
2 ccs/sec 2 secs
6 ccs/sec 8 secs
64 x 0.625, 0.20, 0.35 secs
According to Dr. Foley,
this triphasic injection protocol can be adapted for use
in full thoracic CT, for coronary bypass grafts or suspected
aortic dissection cases, simply by increasing the length
of acquisition by 2 or 3 seconds.
In Dr. Foley's practice,
using a mini-bolus technique, aortic peak is determined from
a time attenuation curve. Then, the time from the beginning of
injection to aortic peak is the circulation time to the mid-ascending
aorta. Four seconds are then allowed from aortic peak on the
mini-bolus until acquisition begins. Dr. Foley stated that there
are two reasons for doing this, "Number one, we know
that aortic attenuation will continue to rise with the longer
duration injection until it reaches a relative plateau at about
4 seconds after the peak from the mini-bolus. The second reason
is if there is any cardiac reactivity to contrast, it's
likely to occur in those first 4 seconds after the aortic arrival.
So it's essential to understand that the bolus that's
injected is not a square wave front bolus, it actually is a sloping
front bolus. So that the reason for delaying for those 4 seconds
is to capture the plateau peak of contrast reached about 4 seconds
after the peak from the mini-bolus."
"We do inject saline rapidly at 6 cc per second. We
inject it for 8 seconds before we acquire data. The reason
for doing that is to clear the superior vena cava. Just to
return to the issue of the second phase of the injection, we
inject deliberately at a slow rate, that's 2 cc per second,
in order to achieve this partial opacification of the right
heart at reproducible attenuation values of about 100-150 Hounsfield
units. So, some opacity of the right heart is necessary in
order that the computer algorithms can separate out the coronary
arterial tree from the background ventricle."
Images and triphasic injection protocol
courtesy of Dennis Foley MD, Medical College of Wisconsin
Ordering Information
Basic System Description EmpowerCTA Double-Barrel Injector Head with Controller, Touch Screen Remote (PC Windows-based) with Desktop Mount, Power Supply, Communications and Power Cables, Pendant Switch.
To order with:
Cat. No.
Units/case
Pedestal Mount with EDA -Basic System with Rolling Floor Stand, EDA Module, EDA Cable.
9900P
1
Ceiling Mount with EDA - Basic System with Overhead Ceiling Mount, EDA Module, EDA Cable.
9900C
1
Pedestal Mount with EDA and EmpowerSync
9900PS
1
Ceiling Mount with EDA and EmpowerSync
9900CS
1
Pedestal Mount - Basic System with Rolling Floor Stand.
9901P
1
Ceiling Mount - Basic System with Overhead Ceiling Mount.
9901C
1
Pedestal Mount with EmpowerSync
9901PS
1
Ceiling Mount with EmpowerSync
9901CS
1
Fast-Load™ Syringes
Disposable 200 mL Fast-Load Syringe with 60" low-pressure extension set and fill tube.For use with EmpowerCT, EmpowerCTA and Fast-Load PercuPump Injector Systems.
6720
50
EmpowerCTA Connecting Tube
A Y-connector with two one-way valves to prevent back flow. To be used to connect both the contrast and saline syringes to one patient extension tube for a procedure that requires the use of both syringes.
7720
25
Empower Transfer Set
Consists of a vented spike, short tube with LUER connect at end and clamp. To be used to facilitate filling a syringe of either contrast or saline. For use with EmpowerCT, EmpowerCTA, and Fast-Load PercuPump Injector Systems with Extravasation Detection capability.
7725
25
EDA Patch
Disposable EDA Patch with access slot. For use with EmpowerCT, EmpowerCTA, and Fast-Load PercuPump Injector Systems with Extravasation Detection capability.
7881
50
Standard Full Service Agreement
Provides full coverage including parts, labor and travel; emergency repair; performance reliability upgrades; one E-Z-EM PM.
FULLSVC
Click here to learn how to have Successful CT Injector Data Management with IRiSCT